Be You Technology

What would you like to know?

ME-TIME · Select all that apply

Prefer to write on WhatsApp?
More about ME-TIMEBenefits · Accessories · Technical data
Be You TechnologyDeveloped by BYT
ME-TIME

Modern technology for facial lifting and contouring

ME-TIME — non-invasive facial firming technology

ME-TIME — non-invasive facial firming technology

ME-TIME combines electrical facial muscle stimulation with simultaneous, controlled RF skin heating. The treatment targets firmer-looking skin, improved muscle tone and more defined facial contours.

Special self-adhesive RF + HIFES electrodes

Special self-adhesive RF + HIFES electrodes

ME-TIME anatomically shaped self-adhesive RF + HIFES electrodes are placed on the forehead and cheeks. They combine radiofrequency and high-intensity electrical stimulation in one applicator, with intensity adjusted to the selected area and the client’s individual tolerance.

Fast, intuitive parameter adjustment

Fast, intuitive parameter adjustment

The clear display allows treatment time and radiofrequency and electrical stimulation intensity to be adjusted from 0 to 100%. Intensities are set separately for the forehead and cheeks. Electrical stimulation frequency is 250 Hz, while intensity is tailored to the selected area and the client’s individual tolerance.

Hands-free treatment

Hands-free treatment

After the self-adhesive electrodes have been positioned and the parameters set, ME-TIME runs the selected program hands-free. The anatomically shaped applicators remain in place throughout treatment, allowing radiofrequency and electrical muscle stimulation to operate simultaneously.

Three anti-ageing goals in approximately 20 minutes

This modern device for non-invasive anti-ageing facial care brings together three goals: firmer-looking skin, improved muscle tone and more defined facial contours. Controlled RF heating combined with muscle activation provides a comprehensive approach to facial care in a treatment lasting approximately 20 minutes.

ME-TIME treatment with self-adhesive electrodes in place

Consumables - electrodes

Each treatment uses a set of 3 electrodes: 1 for the forehead and 1 for each cheek. The electrodes are designed for single use and supplied in individual packs. The standard package contains 31 sets for 31 treatments, together with a USB key for treatment activation. A ME-TIME MAX version is also available with 6 electrodes: 1 for the forehead, 2 for the cheeks, 2 for the eye area and 1 for the under-chin area.

ME-TIME applicators for different facial areas

ME-TIME treatments

Forehead

FOREHEAD — Fine lines · Fresher appearance

ME-TIME care for the appearance of the eye area; electrodes are placed on the designated forehead and cheek areas

EYE AREA — Fine lines · More rested appearance

Cheeks

CHEEKS — Tone · Firmer appearance · More defined contours

Jawline

FACIAL CONTOURS — More defined appearance · Jawline

Lower cheeks

LOWER CHEEKS — Tone · More defined facial contours

Complete facial treatment

COMPLETE CARE — Radiofrequency · Muscle stimulation · Individual program

Who is ME-TIME for?

Who is ME-TIME for?

For people who notice skin laxity, less defined contours and fine lines, as well as those seeking non-invasive treatments. Controlled radiofrequency combined with HIFES high-intensity electrical stimulation provides a non-invasive approach to skin rejuvenation and firming while activating facial muscles.

Training for safe and correct operation

Training for safe and correct operation

Training covers the principles of radiofrequency and electrical stimulation, client assessment and contraindications, correct applicator placement, parameter selection and monitoring responses during treatment.

Operational support, service and regular device inspections

Operational support, service and regular device inspections

Our team is available during business hours for questions about device operation, program selection and treatment organisation. Support and service help you reliably integrate the device into your salon’s daily work.

Technical specifications

Details about the device and its applications are available in our product brochure on request. Technical specifications are based on the supplied ME-TIME brochure.

ME-TIME

ModelME-TIME
Core technologiesRadiofrequency (RF) · High-intensity electrical stimulation (HIFES)
ApplicatorsForehead · Cheeks
Display15.6″
Display resolution1920 × 1080 px
Power supply100–240 V AC · 50–60 Hz
Rated apparent power200 VA
Device dimensions525 × 433 × 1279 mm
Net weight27 kg
Packaging dimensions640 × 560 × 1390 mm
Gross weight55 kg
Additional versionME-TIME MAX · 6 electrodes: 1 for the forehead, 2 for the cheeks, 2 for the eye area and 1 for the under-chin area

RF and muscle stimulation

HIFES output adjustment0–100%
HIFES frequency250 Hz
Electrical stimulation pulse shapeTrapezoidal
HIFES peak voltage60 V
RF output adjustment0–100%
RF power10–100 W
Treatment durationApproximately 20 minutes
Noise levelBelow 60 dB

Consumables - electrodes

Standard package31 sets for 31 treatments
Set for one treatment3 single-use electrodes
Electrode placement1 for the forehead · 1 for the left cheek · 1 for the right cheek
Treatment activationUSB key supplied with the electrode package